Recovery machine
RM12A
RM12C
RM12A
RM12C
Technical Data | ||||
Refrigerants |
Category Ⅲ: R12, R134a, R401c, R406A, R500
Category Ⅳ: R22, R401A, R401B, R402B, R407C,R407D, R408A, R409A, R411A, R411B, R412A, R502, R509
Category Ⅴ: R402A, R404A, R407A, R407B, R410A, R507
|
|||
Power Supply | 220v/50~60Hz | 220v/50~60Hz | 220v/50~60Hz | |
Motor | 1/2HP | |||
Motor Speed | 1450rpm@50Hz | 1750rpm@60Hz | ||
Maximal
Current
Draw |
4A@220v | 8A@100v/110v | ||
Compressor | Oil-less ,Air-cooled , Piston style | |||
Automatic safety
Shut-off
|
38.5 bar/3850kPa(558psi) | |||
Recovery Rate |
Vapor
Liquid
Push/pull
|
CategoryⅢ
0.23kg/min
1.57kg/min
4.64kg/min
|
CategoryⅣ
0.25kg/min
1.81kg/min
5.57kg/min
|
CategoryⅤ
0.26kg/min
1.85kg/min
6.22kg/min
|
Operating
Temperature
|
0℃~40℃ | |||
Dimensions
(VRR12A)
|
500mm x 220mm x 340mm | |||
Weight
(VRR12A)
|
16kg |
Economical recovery with 1/2HP, oil-less compressor.
Suitable for all commonly used refrigerants including R410A. ARI&CE certification approved. 80% overfilling protection.
The unit will automatically stop when the weight of recovered refrigerant reaches 80% capacity of the tank.
Low pressure protection
The unit will automatically stop once the recover is complete,which
reduces the need to monitor the whole process.
Oil separator device
Purification and recycling of the refrigerants.
|